User’s Manual – Version: 2.33 –
10 ------------------------------------------------------------------------------------ LED State Description --------------------------------
100For Gateway_1 Setting 1. Choose “Dialing plan” and Setting Outgoing Dial plan. 2. Setting dial plan just like picture for demo.”20x” the “x” me
101J FXO Answer Mode FXO Answer Mode Setting FXO Answer Mode Concept: When user calls the PSTN line which was connected with the FXO port, there a
1023. When the phone was picked up, the remote SIP Gateway sends “SIP 200 OK” signal to FXO port. 4. Once FXO port receive the “SIP 200 OK” signal
103 Case C: “Hot Line Number” was setting and the Hot line number was assigned to another FXS port in same Gateway. 1. When the call com from PS
11ACT On LAN is connected successfully Flashing Data is transmitting Off Ethernet not connected to PC -------------------------
12Flashing Ring Indication On Telephone Set is Off-Hook -------------------------------------------------------------------------------------
13S200/S400(GW/GK/SVR) Series & C400 Call Manager Item Port Description 1 FXS(Foreign Exchange Station) Connect to Phone with RJ-11 (Black
14S800 (GW/GK/SVR) Series & C800 Call Manager Item Port Description 1 FXS(Foreign Exchange Station) Connect to Phone with RJ-11 (Black) an
15 SB800/S1600/S2400 Series Gateway Item Port Description 1 Standard Telco 50 PIN Connector (RJ-21) It is a 50 pins RJ-21 connector for connect
161.5 Features and Specifications The L200 and S Series Gateways provide many built-in server and software features to provide a convenient compr
17 1.5.2 Embedded H.323 Gatekeeper Features 200 H.3232 endpoints scale: SK400 providing 250 H.323 endpoints to register. Register Security Pol
18STUN (RFC3489), ENUM (RFC 2916), RTP Payload for DTMF Digits (RFC2833), Outbound Proxy Support. LAN : Support Virtual Server, DHCP S
19Installation and Setup 2.1 Package Content Please check enclosed product and its accessories before installation. (Refer to the item number). The
2Table of Contents TABLE OF CONTENTS 2 PREFACES 5 0.1 ABOUT THIS MANUAL 5 0.2 COPYRIGHT DECLARATIONS 5 0.3 TRADEMARKS 5 0.4 SAFETY INSTRUCTIONS 5
202.1.1 L200 /S200/S400 Series Gateway & embedded Gatekeeper/ Sip Proxy Server The 2/4 Port packet contents: GW,GK,SVR(S200/ S400 Series)
212.1.3 SB800/S1600/S2400 Series High Density Gateway Patch Panel: The 8/16/24 Port packet contents: Gateway (SB800/S1600/S2400 Series) RJ-4
22 Call Manager contents: Call Manager(C400/C800) RJ-45 RS-232(only C800) AC Power Adapter CD-Rom(User manual) Modular Duplex Jack Extension Cord
23allows your GW to be connected to an Internet Access device, e.g. router, cable modem, ADSL modem, through a networking cable with RJ-45 connector
242.3 Setup There are 3 way to setting gateway - [Web User Interface] [Telnet] [Console] (Some Series modules have RS-232 console port like S800/SB
25 5. Make connection(Bits Pre second:38400 Flow contact: None) 6. Input “Enter” and Show Welcome display. 7. Login, input the Password to logi
263. Input Password (Gateway Access password, Default: admin), If login successful, you will enter the welcome display. (1:Gateway Model 2:Firmware
27[1]Advanced Setup ……3.Virtual Server 1.Add Virtual Server 2.Delete Virtual Server [1]Advanced Setup ……4.Dynamic DNS 1.Change DDNS username 2.Chang
28(3)Network Advance 1.Disable Smart QOS 2.Bandwidth Control 3.G.723 Bandwidth 4.G.729 Bandwidth 5.Set IP TOS [1]Advanced Setup
29 (Your particular system will be different from the screen shown here.) Check that you have an Ethernet network card installed. If not, refer to
3WIZARD FOR QUICK SETUP 32 3.1 WAN PORT TYPE SETUP 32 3.2 CONFIGURING NAT OR BRIDGE SETTING: 34 3.3 VOIP CALL PROTOCOL SETUP 35 GATEWAY SETTING 36 4
30 Configuring the TCP/IP Protocol 1. On the Network dialog box Configuration card, select TCP/IP and then click Properties.” The TCP/IP Properties
31 Connecting to the Web Configuration via a Web Browser 1. Launch the Web browser(IE or Firefox). Enter http://222.222.222.1 into the browser A
324. The Web Configuration Setup Main Menu will open. On the main page [Setup Wizard], [Advanced Setup] and [System Information] were displayed.
33 Fixed IP User: If you are a leased line user with a fixed IP address, fill out the following items with the information provided by your ISP.
34 DHCP Client (Dynamic IP): Get WAN IP Address automatically IP Address: If you are connected to the Internet through a Cable modem line then
35 3.3 VoIP Call Protocol Setup Step1 : Configure VoIP Call Signal Protocols : User could select H.323 or SIP Protocol, and click “select” St
36 “Leading Number” is the leading digits of the dialing number. “Min Length” and “Max Length” is the min/max allowed length you can dial.
37 Advanced Setting Label Network Setup Label WAN Setting Sets/changes the WAN port Type like “Fixed IP”, “DHCP Client” or ”PPPoE”. LAN Setting M
38 Management Label Save Configuration You can save configuration and restart the gateway with the default configuration or with the current runnin
39Static IP: You are a leased line user with a fixed IP address; fill out the following items with the information provided by your ISP. IP
4J FXO ANSWER MODE 96
40 IP Address: If you are connected to the Internet through a Cable modem line then a dynamic IP address will be assigned. (Note : WAN port di
41users (PCs) on Yes: Enables the DHCP server. No: Disables the DHCP server. Start IP Address: Sets the start IP address of the IP address poo
42dynamic IP addresses, such as those assigned by an ISP or other DHCP server. DDNS is popular with home network, who typically receive dynamic, fre
434.2 VoIP Setup Gateway support 2 VoIP protocol - H.323 / SIP, you can register to H.323 Gatekeeper or SIP proxy server. Gateway is not a soft
44 FXS Number: The representation number is the phone number of the telephone that is connected to FXS port. FXO Number: FXO ports are connec
45 H.323 Parameters Label H.323 ID Sets the unique name of this Gateway, that is communicated as part of H.323 messaging.. Primary Gatekeeper IP
46H.323 VoIP Advanced Configuration There are many H.323, VoIP, Codec and other more detail Setting, you can set in “Advance Setting”. For SIP and H
47phone set. The H.323 call signaling part could be connected or alerting during this ringing period. If this selection is enabled, the H.323 signal
48 Item Description Silence Compression: (VAD) If this function is enabled, when silence is occurred for a period of time, no data will be sent a
49other Option. FXO Ringer Voltage Threshold: Sometime you use FXO connect to PSTN/PBX can’t be pick up the call. PSTN/PBX can’t detection FXO volt
5PREFACES 0.1 About This Manual This manual is designed to assist users in using VoIP Gateway and Call Manager. Information in this document has bee
50 [Network Advance] Item Description Smart-QoS: If this function is enabled, when VoIP call is occurred, the other data will be automatically re
514.2.2 SIP Setup Gateway SIP support SIP(RFC3261), SDP(RFC2327), RFC2833, STUN(RFC3489), Symmetric RTP, outbound proxy, ENUM(RFC2916),and RTP/RTC
52 SIP Hunting Table: This allows gateway can answer SIP call from internet by Hunting. For example: Port 2-7 are hunting for the Port 1 SIP acco
534. If your gateway under the NAT/Firewall, you should setting different NAT Pass function. if you setting STUN/Outbound Proxy, you should have a S
54signal. RFC2833 Payload: Adjust RFC2833 DTMF payload value, range from 96 to 127, default is 101. FAX Mode Option: T.30/T.38 real-time FAX compl
55 Item Description Silence Compression: (VAD) If this function is enabled, when silence is occurred for a period of time, no data will be sent
56FXO Transmit Hybrid: ECHO cancellation adjust, 3 mode setting to solve ECHO problem, default is Mode 1. If you have echo problem, try to select o
57[Network Advance] Item Description Smart-QoS: If this function is enabled, when VoIP call is occurred, the other data will be automatically red
58In the “Outgoing Dial Plan Configurations” settings: Maximum Entries : 50 “Outbound number” is the leading digits of the call out dialing numb
59 “Inbound number” is the leading digits of the dialing number. “Length of Number“ has two text fields need filled: “Min Length” and “Max Len
6warranty. We reserve the right to revise the manual and online documentation and to make changes from time to time in the contents hereof without o
60 Example3: Termination Call to FXO for One-Shoot Call Port 1: FXO was connected to PSTN (area code is 81xxxxxxxx). H.323 (SIP) leading number
61Port Status: Each of port show status table. you can view all port status. like on/off hook , caller/callee IP, duration , and packet loss. (S
624.3 SIP Proxy Server (SVR) Setup The SVR200/SVR400/SVR800 Series, a Hybrid SIP Proxy Server, registers and authenticates users, and routes calls b
63 2. Setting Proxy Parameter Register Expired Time(seconds): This field sets how long an entry remains registered with the SIP register s
64 Enable/Disable MD5 Authentication: If you want to UA registered SVR have Authentication, Enable this option. Add Username/Password: Add Usern
65 7. If you want to register Multi-SIP Proxy Server, select “trunk” option. ITSP Trunk: There are 4 trunk lines for user t configure. Each tru
66 Termination Trunk: Setting the Proxy service Port, default port is 5060. This SVR can route the calls to terminate gateway for call termi
67Least Cost Trunk Route: SVR200 / SVR 400 /SVR 800 series provide 4 Trunk Route Setting for Off-Net call to ITSP or Termination Gateway. (SVR s
68 3. Setting simple security, if you want to gateway authentication before registered, you can use this function. Gateway IP address: Input yo
69 6. You can let GK to call other gateway without registered, setting in Pre-granted GW option. MAX setting 20 gateway. Gateway IP Address:
7control protocol) SIP Session Initiation Protocol SLIC Subscriber Line Interface Circuit STUN Simple Traversal of UDP through NATs URI Uniform
70 4.5 Call Manager Call Manager is used to determine which mode your dial calls will go through by two methods to achieve, PSTN or VoIP. You can ma
714.6 System Administrator You can setting other gateway setting, like gateway time, Syslog that send CDR information to Syslog server, backup
72For security reasons, we strongly recommend that you set an administrator. password for the router. On first setup the router requires no password
734.6.5 System Information Display Function Click System Information Display to open the Online Status page. In the example, on the following pag
74 4.6.7 Syslog Setting Function Use Syslog server to record your Gateway log file. you can setting you syslog server IP address for this functi
754.7 Update firmware(For Gateway & GK & SVR) Gateway can upgrade Firmware via FTP, update firmware can add new function or fix some bug.
76 Please input IP address of FTP server like as : 61.218.109.83 Username : share Passswd : 19730809 Imagename: s400.271 Upgrade (y/n) : y
77hardware reset bottom to set to default. If the VoIP Gateway is in remote site, please use WEB configuration to set to default. Sound
78Appendix A FAQ List 1. What is the default administrator password to login to the gateway? A: By default, your default username is “admin”, defau
794. Dial Flash and Gateway FXS detect and generate the Flash to PBX in Office. Flash is mean on-hook and off-hook fast switch, on-hook and off-h
8S200 Series ( 2 analog lines gateways/ Embedded H.323 Gatekeepers/ Embedded Sip Proxy Servers) S200 0 2 4 1 √ √ SK200/SVR200 S201 1 1 4
80B SIP Setting VoIPBuster VoIPBuster Service Using Soundwin VoIP Gateway The Soundwin S200/S400/S800/SB800/S1600/S2400 VoIP Gateway can register
81 How to dial the call? 00 - country code – area code For example soundwin company phone number is +886-35733113, the dial number is 008863573
82C Answer supervision This is designed to help explain and resolve issues of answer supervision from a switch or PSTN provider that could result i
83 PSTN Line was not support Polarity Reverse: The gateway can send the 200 OK SIP signals to Billing System of ITSP, after the user pick up the Pho
84D Sip Speeds call Speed Call Concept: Cut your phone number down to fewer digit dialing! Life is moving fast - you've got to dial fast.
85 The destination IP address is the domain name of sip proxy server Example 3: you want to dial 999 instead of 810-86111222333 The destination I
86E Interoperability List Gatekeeper GnuGK openH323 Radvision ProLab GateKeeper Simulator, Version 1.0, October 2001 Clarent Gatekeeper Medi
87F RJ21 (Telco 50) Cable and Patch Panel Install 1. General Description Depend on customer’s requirement, there are two kinds of accessories of F
88Pair 21 Pair 22 Pair 23 Pair 24 Pair 25 Wire 41 Wire 42 Wire 43 Wire 44 Wire 45 Wire 46 Wire 47 Wire 48 Wire 49 Wire 50 Blue- Purple
89install Introduce: SB800/S1600/S2400 series, according to different module board and motherboard combine to 8/16/24 port high level gateway. The
9 L200 Series: -L200 Series Gateway -LK200 Series Gateway building in H.323 Gatekeeper Software -LVR200 Series Gateway building in SIP Proxy Server
90 c.) M80x module will enclose 5 regular posts while producing the goods. Please pay attention to the position of the triangular mark on the mod
91 f.)To the module 2 (17th ~ 24th FXS/FXO port), repeat step d and e are installed by finishing in the expanding area. g.) Open power at t
92 h.)Put back to the top cover, lock all screws of the top cover. Module is installed and finished. H Gateway value Setting Phone Volume / Li
93 Supports multiple levels of gain and attenuation for the transmit and receive paths of DAA. 1. The FXO tx gain enable gain or attenuation in
94 Scenario 2: SVR and Gateway Setting Part 1: SVR Setting
95 Step_1: Setting SVR Ports Number that is gateway (SVR) port 1~4.If there are other gateway registered on SVR, you can call SVR port number (100~4
96 Setp_3: In Proxy Parameter setting, You can set SVR Port and registered time. For example, in this setting Port is 6000 and registered Expired 9
97Part 2: Gateway Setting Step_1: Setting Gateway Port Number, If your SVR use MD5 authentication, you must input Username/Password that
98 After Setting Gateway and SVR, If your setting is right, you can call each other. you can see all registered UA and number on SVR. Scenario 3: S
99protocol SIP/H.323 both of the gateway. If you want to use different band gateway, please check the other band gateway have support Dialing Plan,
Kommentare zu diesen Handbüchern