DynamixUM‐SNBUserManualVer1.0074
4.5 UM-SNB/703/UM-SNB/703/4w
4.5.1. UM-SNB/703 / UM-SNB/703/4w E1+T1 interface model -- E1 Interface mode
Interface
⊠E1 □T1
NTU
Type
□STU-R □STU-C-INTCLK □STU-C-EXTCLK
Annex □A □B □F □G
PSD □SYM □ASYM
SNR Margin (-10~21)
SHDSL
Pair Mode □1 Pair □2 pair (For UM-SNB/4in1/4w only)
Channel □PCM31 □PCM31C □PCM30 □PCM30C □Unframed
Pass Through □Off □On
Slot Number
First Slot
Code □HDB3 □AMI
AIS □Off □On
E1
Build Outs □75 Ohm □120 Ohm
When SHDSL.bis using 2-pairs(4-wires), the E1 time slot number can only use even number
When E1 framer is PCM31C and PCM30C and set pass through ON, no fractional function can be use.